ADIABATIC COOLING KIT & PRE-COOLING OF AIR COOLED CONDENSOR

Installing our unique adiabatic pre-cooling misting system can reduce the temperature by maximum up to 12° C in chiller units, significantly improving the operating performance and efficiency of the air-conditioning units by as much as 29%.

ADIABATIC COOLING KIT & PRE-COOLING OF AIR COOLED CONDENSOR

TrueMIST Evaporative Cooling systems are Cost-Effective, Efficient, and controllable which are effective in reducing in energy consumption of large Air Conditioner chiller units for Industrial and commercial places.  HVAC Pre Cooling misting makes the AC Chillers energy efficient.

Air-conditioning units are put to work when the heat is on. During these hot months of summer, they're under constant pressure and load to circulate enough cool air for your comfort zone! When the temperature outside heats up, so does electricity usage by AC chiller units; not only that but their cooling capacity will decrease as well.

Following are the advantage when the AC condenser unit runs efficiently with help of HVAC Pre Cooler Misting:
- Less energy consumption
- Releasing of fewer greenhouse gases
- Water savings
- Cost-saving and Economical as a result of less energy and water usage

Suitable for :

- Refrigeration units
- HVAC Condenser pre-cooling misting (Heat and Ventilation Air Conditioning System)
in Commercial and industrial air-conditioning
During the hot weather months, units are under constant pressure to circulate enough cool air to the area where it is needed. Put simply when air temperature increases, electricity consumption in air-conditioning units increases substantially and in addition to this process, the cooling capacity of the air-conditioning unit decreases.

Intelligent Adiabatic Pre-Cooling System Brochure

The increased load placed on the AC Chiller system results in

Poor performance.
Untimely shutdowns.
Compromised product quality.
Reduction of air-conditioning performance.
Increased electricity consumption.
Severe stress on Electrical and mechanical parts, shortening the lifespan of the air-conditioning Chiller unit.
Excessive loads on the condensing coil of the AC Chiller unit from extreme heat may cause the eventual shut down of the air-conditioning unit.

By installing an Adiabatic Misting System / HVAC Pre-cooling system, Customer benefits in following ways

Outside air temperature into the unit is lowered by up to 12°C.
Energy consumption dips, save electricity, and is economical as much as 23%.
Increases the efficiency of the air-conditioning Chiller unit by 29%.
Reduces system downtime.
Improves occupant comfort level.
Substantially extends the life time of all Air Conditioning units.
Environmental benefits – lower consumption kW reduce carbon footprint.

FAQ

How does it compare to conventional cooling?

You save 29% Energy and reduce electricity bills.

Is it an Environment conscience product?

Yes it is a GREEN Product which improves Energy Efficinecy Ration (EER) by 20%

Does it reduce water consumption?

Misting system for Chiller units reduce water consumption by up to 80%

How to install a Misting System for AC Pre-Cooling system?

With the help of fine misting nozzles placed in a line in front of the condenser coils to pre-cool the intake air passing through the condenser coils.  When connected to a high-pressure misting system pump, water is forced through the specialty nozzles and atomizes the droplets to as small as (5 microns).
Misting systems will produce tiny droplets instantly. If these droplets are introduced into a hot outdoor area, they quickly evaporate in the atmosphere. This process of evaporation requires energy to be completed. The energy is taken from the air in the form of heat. The result is a temperature reduction of up to 12 degrees on the condenser area, depending on the ambient temperature and the relative humidity in the air. This method of temperature reduction is the most common use for all misting systems.

The cold air passed across the Chiller condenser coil improves the heat transfer efficiency; the unit needs less amount of power to run.
Tags: Adiabatic Misting Systems, Adiabatic cooling kit, Adiabatic pre-cooling system, misting system for chiller units